![]() ![]() You will be responsible for moving the shipment into your address, unpacking, and disposing of packing material. Please note that freight delivery does not include bringing the shipment inside your address, unpacking, or disposing of packing material. The item will arrive secured to a pallet and delivered up to your address. Freight: For oversized items, the freight cost is $545 per item.Alarm Disabled During Priming: Air-in line.Maximum Volume Infused Under Single-Fault Conditions: CADD administration set - 0.15 ml.Actual Test Data for Bolus Accuracy at 20 ml:.Actual Test Data for Bolus Accuracy at 0.05 ml:.Accumulated Air: Greater than 1 ml air over 15 minutes (nominal).High - Single bubble greater than 150 μL.Low - Single bubble greater than 400 μL.High Pressure Alarm Threshold: 18 ± 9 psi (1.24 ± 0.62 bar).During the total infusion time, the accuracy averages out. At low infusion rates, this accuracy may not be achieved for short periods. System Delivery Accuracy: ± 6% (nominal).Atmospheric Pressure: 70 to 106 kPa (10.2 to 15.4 psi).Relative Humidity: 20 to 90% relative humidity, non-condensing.System Storage and Transportation Temperature: -20 to 60 ☌ (-4 to 140 ☏).System Operating Temperature: 2 to 40 ☌ (36 to 104 ☏).Power Sources: 4 AA (IEC LR6) alkaline batteries, AC adapter, rechargeable battery pack.Note: Values are nominal and based on actual test data.10 ml/hr - medication cassette reservoir: 44 seconds.0.1 ml/hr - medication cassette reservoir: 108 minutes.Maximum Infusion Pressure: 27.0 psi (1.86 bar).Moisture Protection: Splashproof (IPX4) per IEC 60529.This is only enabled while the pump is in run mode. Battery Fallout Alarm: Alarm sounds for two minutes if the pump has been powered up for a minimum of two minutes.Pump Alarms: The following alarms are all considered to be high priority alarms, battery depleted while delivering, battery removed while delivering, battery unusable while delivering, rechargeable battery end of life, disposable detached while delivering, disposable attached improperly, disposable type high flow administration set, disposable type invalid, disposable locked but not latched, reservoir volume empty, pressure sensor faulty, downstream occlusion, upstream occlusion, air in line detected, remote dose cord key stuck, stop mode reminder, pump was automatically stopped.Weight: 595 g (21 oz) including 4 AA alkaline batteries, excluding other accessories.Size: 4.1 cm x 10.2 cm x 12.7 cm (1.6" x 4" x 5") excluding cassette or other accessories.Resolution: Medication cassette reservoir or CADD administration set, 0.05 ml per pump stroke nominal.Graphs and reports provide trending data and delivery history for patient assessment and continuous quality improvement.Smiths Medical CADD Solis PCA 2110 Ambulatory Pump Specifications.The patient-focused user interface may help reduce training time by providing therapy related information in an easy to understand format.Developed with reliable CADD ® pump technology that meets industry standards for infusion pumps.Infusion data is collected for additional pump documentation, reporting and CQI data analysis. The application is used to securely program the CADD ®-Solis VIP pump saving Pharmacist and Nursing time in manually programming the infusion pump. The pump delivers via the following delivery profiles: PCA, continuous, intermittent, variable stepped rate, and tapered infusions for analgesia, chemotherapy, hydration, antibiotics, immune globulin, and TPN.ĬADD™-Solis Medication Safety Software Administrator Program: Administrator software is a Windows ® based application used by select staff members to create and manage the standardized pump protocols. The pump can be programmed with a protocol configuration consisting of a therapy, qualifier and drug information. The CADD ®-Solis VIP (variable infusion profile) Ambulatory Infusion Pump is designed to facilitate patient care for a variety of adult and pediatric patients and clinical care areas. ![]()
0 Comments
Leave a Reply. |